Catalog / Transformers & Components
Transformers & Components
Dry-type transformers
Dry-type transformers (including VPI and cast-resin designs) are often specified where oil-filled units are not preferred. KVAScout sources to the kVA, voltage, insulation system, enclosure, and test requirements in the specification. Listing and efficiency documents are reviewed against the applicable standard for the voltage: UL 1561 is used for units rated 600 V and below; UL 1562 covers dry-type distribution transformers with a winding of 601–35,000 V.
Category details
- Typical ratings and voltage range
- From small specialty units to several MVA, as specified. Voltage may be low voltage (≤600 V) or medium voltage. Review items include insulation system (VPI or cast resin), ventilated or sealed construction, kVA, voltage and BIL, temperature rise, enclosure, and efficiency documentation where DOE Subpart K applies. Applicable voltage classes: Low voltage (1 kV and below), Medium voltage (greater than 1 kV and less than 100 kV).
- Standards buyers commonly specify
-
- IEEE C57.12.01
- IEEE C57.12.51
- IEEE C57.12.52 (sealed dry-type power transformers; typically outside the DOE distribution-transformer definition)
- IEEE C57.12.91
- UL 1561 (dry-type general purpose and power transformers, 600 V and below)
- UL 1562 (dry-type distribution transformers with 601–35,000 V windings)
- DOE 10 CFR 431 Subpart K, where the unit meets the definition in 10 CFR 431.192 (typically primary ≤34.5 kV, secondary ≤600 V, 60 Hz, liquid-immersed 10–5,000 kVA or dry-type 15–5,000 kVA; autotransformers, sealed units, rectifier transformers, and certain other types are excluded and must be checked unit by unit)
- IEC 60076-11 (when an IEC cast-resin specification is used)
These are standards buyers often name in a specification. KVAScout is not a certification body and does not issue listings.
- What we review with the supplier
-
- kVA, voltage, and BIL
- Insulation system and ventilated or sealed construction
- Temperature rise and enclosure
- Whether DOE 10 CFR 431 Subpart K applies to the unit
- Test records under IEEE C57.12.91 or the specified equivalent
Values come from the specification or from supplier documents. They are not catalog ratings, stock figures, or prices.
- Used in
- Renewable generation, Distribution grid, Commercial & industrial, Data centers, Real estate & buildings, Energy storage projects
- Supplier listings
- No supplier listings are published for this category yet. When listings are added, they will be reviewed against the standards and scope noted on this page, and they will appear here with origin, rating, and documented availability. We do not invent stock, prices, certifications, lead times, or partner names.
How we source
Equipment is sourced from qualified supply chains in the United States, Europe, Japan, Korea, Mexico, and other markets, according to each buyer's origin, funding, and compliance requirements. Whether a given origin is eligible for a project is reviewed with the buyer before a firm quotation. Buyers are primarily in the United States; we also serve qualified buyers in other countries. We do not publish inventory or prices on this site, and we do not list suppliers as partners.