Applications / Generation / Renewable generation

Application

Renewable generation

Renewable plants often need collector and inverter-related transformers, medium-voltage switchgear, cable, and, where specified, inverters or storage. This page lists categories already in the catalog that are commonly used on those projects.

Categories in this application

Only categories already in the catalog are listed. We do not invent product types for an application.

Gas-insulated switchgear (GIS)

Gas-insulated switchgear from medium-voltage installations through compact high-voltage and EHV substations.

>1 kV to <100 kV100–230 kV>230–765 kV

Disconnect and isolating switches

Disconnect, isolating, and grounding switches from medium voltage through EHV. These devices are not circuit breakers and are not rated to interrupt short-circuit current unless a load-break function is separately specified.

>1 kV to <100 kV100–230 kV>230–765 kV

Instrument transformers (CT, PT, CCVT)

Current, voltage, and coupling capacitor voltage transformers for metering and protection.

>1 kV to <100 kV100–230 kV>230–765 kV

Surge arresters

Distribution- and station-class metal-oxide surge arresters for systems above 1 kV.

>1 kV to <100 kV100–230 kV>230–765 kV

Medium- and high-voltage cable

Power cable and accessories for medium- and high-voltage circuits, including extruded systems through 500 kV where specified.

>1 kV to <100 kV100–230 kV>230–765 kV

Generator step-up (GSU) transformers

Step-up transformers that connect a generator to the transmission system, typically 69 kV class and above.

>1 kV to <100 kV100–230 kV>230–765 kV

Dry-type transformers

Cast-resin and ventilated dry-type transformers for indoor and special environments, including low-voltage and medium-voltage designs.

≤1 kV>1 kV to <100 kV

Transformer bushings

Condenser and related bushings used on power and distribution transformers and other oil-filled equipment.

>1 kV to <100 kV100–230 kV>230–765 kV

On-load tap changers (OLTCs)

On-load tap changers and related drive and monitoring equipment for power transformers.

>1 kV to <100 kV100–230 kV>230–765 kV

Transformer cores and grain-oriented electrical steel

Cores and grain-oriented electrical steel (GOES) used in power and distribution transformers, sourced against the buyer’s grade and loss specification.

Transformer radiators and cooling equipment

Radiators, fans, pumps, and related cooling equipment for liquid-immersed transformers.

>1 kV to <100 kV100–230 kV>230–765 kV

Insulating oil

Mineral and alternative insulating liquids for transformers and related equipment, sourced to the specified fluid standard.

Medium-voltage metal-clad switchgear

Metal-clad switchgear for medium-voltage indoor and outdoor service, typically 4.76–38 kV class, with current standards covering assemblies through 48.3 kV.

>1 kV to <100 kV

Metal-enclosed switchgear

Metal-enclosed interrupter and load-interrupter switchgear for assemblies above 1 kV.

>1 kV to <100 kV

Vacuum circuit breakers

Vacuum circuit breakers for medium-voltage switching and protection, typically 4.76–38 kV class.

>1 kV to <100 kV

Protection relays

Protective relays and related control devices specified for power-system protection.

≤1 kV>1 kV to <100 kV100–230 kV>230–765 kV

Substation e-houses and skids

Prefabricated electrical houses, skids, and packaged modular substations.

≤1 kV>1 kV to <100 kV

Battery energy storage systems

Scarce battery energy storage equipment and related containers or modules, sourced to the buyer's specification.

≤1 kV>1 kV to <100 kV

Inverters and power conversion systems (PCS)

Inverters and power conversion systems used with solar, storage, and related generation.

≤1 kV>1 kV to <100 kV

BESS, solar, and inverter-related MV transformers and skids

Inverter-duty transformers and medium-voltage skids used with solar, storage, and collector systems.

≤1 kV>1 kV to <100 kV

Pad-mount distribution transformers

Ground-mounted distribution transformers for underground and pad-mounted service. These are medium-voltage distribution transformers on the primary; the secondary is typically low voltage.

>1 kV to <100 kV

Unit and box substations

Packaged unit substations and box-type substations that combine a transformer with medium-voltage and/or low-voltage gear.

≤1 kV>1 kV to <100 kV

How we source

Equipment is sourced from qualified supply chains in the United States, Europe, Japan, Korea, Mexico, and other markets, according to each buyer's origin, funding, and compliance requirements. Whether a given origin is eligible for a project is reviewed with the buyer before a firm quotation. Buyers are primarily in the United States; we also serve qualified buyers in other countries. We do not publish inventory or prices on this site, and we do not list suppliers as partners.