Generation
Equipment used at power plants, including thermal, gas-turbine, nuclear, and renewable generation.
Catalog
Start from how the equipment will be used, from the product family, or from voltage, capacity, and standard. The catalog is focused on medium- and high-voltage equipment through 765 kV. It is not a stock list and it does not include prices. If we can source an item, we will say so in a quote after human review.
1 · By application
Open an application to see the categories we already source for that kind of project.
Equipment used at power plants, including thermal, gas-turbine, nuclear, and renewable generation.
Equipment for transmission lines and substations, through 765 kV.
18 categories
Equipment used on the medium-voltage distribution system, including pad-mount and pole-mount transformers, reclosers, and MV switchgear.
22 categories
Equipment used on the customer’s side of the meter: commercial and industrial sites, data centers, buildings, and storage projects.
2 · By product
Families such as transformers are split into generator step-up, grid and substation, distribution, and user-side service.
Power, GSU, distribution, and user-side transformers, plus key components.
12 categories
GIS, metal-clad and metal-enclosed switchgear, LV gear, and packaged substations.
6 categories
High-voltage, vacuum, and distribution interrupting equipment, plus disconnects.
4 categories
Medium- and high-voltage cable, metal-enclosed bus, and low-voltage busway.
3 categories
Gas turbines, generators, and nuclear-power sourcing support.
3 categories
Battery systems, inverters and PCS, and related medium-voltage transformers.
3 categories
Relays, instrument transformers, arresters, capacitor banks, and reactors.
5 categories
Machines and systems used to manufacture power equipment.
4 categories
Verified in-stock, surplus, and refurbished equipment, documented before an offer is issued.
1 category
3 · By parameters
The address bar updates as you filter, so a view can be shared. Capacity and standard match the text published on each category page.
Voltage classes on this catalog follow ANSI C84.1 for a U.S. buyer audience: low voltage is 1,000 V or less; medium voltage is greater than 1 kV and less than 100 kV (including 38 kV class, 46/48.3 kV class, and 69 kV / 72.5 kV class); high voltage is 100–230 kV; extra-high voltage is greater than 230 kV and less than 1,000 kV. This catalog is focused on medium- and high-voltage equipment through 765 kV. It does not list UHV (1,000 kV and above) as a separate class. Low voltage appears only for a few genuinely scarce items.
Power transformers for substation step-down, step-up, and autotransformer service, including distribution-substation and transmission voltages.
Dead-tank and live-tank circuit breakers for 69 kV class through EHV substations, including SF6 or alternative-gas designs as specified.
Gas-insulated switchgear from medium-voltage installations through compact high-voltage and EHV substations.
Disconnect, isolating, and grounding switches from medium voltage through EHV. These devices are not circuit breakers and are not rated to interrupt short-circuit current unless a load-break function is separately specified.
Current, voltage, and coupling capacitor voltage transformers for metering and protection.
Distribution- and station-class metal-oxide surge arresters for systems above 1 kV.
Shunt and harmonic-filter capacitor banks for voltage support and power factor, from medium voltage through EHV.
Shunt, series, and neutral reactors for substations and collector systems.
Isolated-phase, non-segregated, and segregated metal-enclosed bus under IEEE C37.23, typically 1,058 V to 38 kV.
Power cable and accessories for medium- and high-voltage circuits, including extruded systems through 500 kV where specified.
Step-up transformers that connect a generator to the transmission system, typically 69 kV class and above.
Cast-resin and ventilated dry-type transformers for indoor and special environments, including low-voltage and medium-voltage designs.
Condenser and related bushings used on power and distribution transformers and other oil-filled equipment.
On-load tap changers and related drive and monitoring equipment for power transformers.
Cores and grain-oriented electrical steel (GOES) used in power and distribution transformers, sourced against the buyer’s grade and loss specification.
Radiators, fans, pumps, and related cooling equipment for liquid-immersed transformers.
Mineral and alternative insulating liquids for transformers and related equipment, sourced to the specified fluid standard.
Metal-clad switchgear for medium-voltage indoor and outdoor service, typically 4.76–38 kV class, with current standards covering assemblies through 48.3 kV.
Metal-enclosed interrupter and load-interrupter switchgear for assemblies above 1 kV.
Vacuum circuit breakers for medium-voltage switching and protection, typically 4.76–38 kV class.
Protective relays and related control devices specified for power-system protection.
Prefabricated electrical houses, skids, and packaged modular substations.
Industrial and power-generation gas turbines, sourced to the buyer's rating and project specification.
Synchronous and related generators for new-build and replacement service, including units paired with turbines or engines.
Scarce battery energy storage equipment and related containers or modules, sourced to the buyer's specification.
Inverters and power conversion systems used with solar, storage, and related generation.
Inverter-duty transformers and medium-voltage skids used with solar, storage, and collector systems.
Sourcing support for scarce nuclear-power electrical and related equipment, under the buyer's quality program and export-control review.
Ground-mounted distribution transformers for underground and pad-mounted service. These are medium-voltage distribution transformers on the primary; the secondary is typically low voltage.
Overhead distribution transformers for pole-mounted service. These are medium-voltage distribution transformers on the primary.
Automatic circuit reclosers for medium-voltage distribution, typically above 1 kV through 38 kV.
Packaged unit substations and box-type substations that combine a transformer with medium-voltage and/or low-voltage gear.
Low-voltage switchgear and switchboards for service and distribution at 1 kV and below, when the item is scarce or long-lead.
Low-voltage busway (bus duct) typically 1,000 V and below, specified to UL 857 or IEC 61439-6.
Cut-to-length, slitting, and stacking lines used to manufacture transformer cores.
Winding machines used to manufacture transformer, reactor, and related coils.
Vapor-phase and related drying ovens used in transformer manufacturing and rewind shops.
Test systems used to factory-test transformers, switchgear, and related power equipment.
Documented in-stock, surplus, and refurbished units when a new-build lead time will not meet the project.
Equipment is sourced from qualified supply chains in the United States, Europe, Japan, Korea, Mexico, and other markets, according to each buyer's origin, funding, and compliance requirements. Whether a given origin is eligible for a project is reviewed with the buyer before a firm quotation. Buyers are primarily in the United States; we also serve qualified buyers in other countries. We do not publish inventory or prices on this site, and we do not list suppliers as partners.
Tell us the application, category, rating, voltage, quantity, and need-by date. A person will review the request.
Request a quote